- Description
Operation Video,
The wavelength of Holmium Laser is 2.1 μm, at the peak of water absorption. The laser energy can be highly absorbed by water in tissue and calculus. Through small evaporation explosion in stones and parenchyma vaporization, it could be used to shatter stones or conduct tissue incision. As the penetration depth of holmium laser in tissue is less than 0.4mm, there will not be a mistaken incision and perforation or other complications in operation, which assures the operation safety. Holmium laser could be widely used in urinary surgery, dermatology, gynecology, gastroenterology, general surgery, ENT .etc.
Parameters as follows:
Holmium laser photoelectric characteristics:
1, "CE" certification, the quality of the most stable, the only domestic holmium laser certified by CE).
2, energy power closed loop feedback control system, automatic monitoring of output power to ensure that accurate and stable output power
On the basis of energy feedback system based on the re-use of accurate power loop control system, real-time monitoring of power changes, real-time adjustment of energy; ensuring a more stable power output.
3, the only photovoltaic holmium laser energy also has a closed-loop control system and built power stabilizer technology to ensure a stable output laser energy for a long time
4, with patented airtight laser cavity design technology
shock, moisture, dust, anti-electromagnetic interference, to create a good working environment for the activation of the elements holmium ensure holmium laser output quality, but also to ensure long-term stability of the laser output.
5, advanced fiber coupling technology
For a variety of specifications (200,300,400,600,800,1000μm) fiber conduction. East Cape photoelectric 200μm fiber through the CE certification, excellent flexibility, to maximize the soft lens curved to follow, with the energy of a closed-loop feedback control system, the output energy precise, stable and safe.
6, Quiet environmentally friendly forced cooling system
European imports host, ultra-quiet design, fast strong freon compressor refrigeration technology, remained stable. Make long continuous multiple laser surgery, without rest, domestic manufacturers in the longest continuous operation.
7, modular design, first-class laser individually removable, easy maintenance
Laser cavity, circuit control systems, power systems, cooling systems, display systems and other components using a modular approach designed to facilitate maintenance, while also reducing maintenance costs.
8, imported core components, quality assurance
Imported core components make the pump uniform, high conversion efficiency, high power holmium laser treatment, ultra stable, perfect performance and long life to provide a reliable guarantee.
9, color touch-screen LCD
Large screen, simple operation, at a glance, every 0.1 watts of power change real show
Standard Configuration,
Click here to download the User Manual,
/u_file/1902/file/d35b4443e5.pdf
The wavelength of Holmium Laser is 2.1 μm, at the peak of water absorption. The laser energy can be highly absorbed by water in tissue and calculus. Through small evaporation explosion in stones and parenchyma vaporization, it could be used to shatter stones or conduct tissue incision. As the penetration depth of holmium laser in tissue is less than 0.4mm, there will not be a mistaken incision and perforation or other complications in operation, which assures the operation safety. Holmium laser could be widely used in urinary surgery, dermatology, gynecology, gastroenterology, general surgery, ENT .etc.
Parameters as follows:
Model | 40W | 70W | 80W |
Output power | 2.5-40W | 2.5-70W | 2.5-80W |
Pulse energy | 0.5-4.0J | 0.5-4.0J | 0.5-4.5J |
Repetition rate | 5-20Hz | 4-40Hz | 4-40Hz |
Wave length | 2100nm | ||
Aiming beam | 532nm Green, Optional 635nm Red | ||
Optical fiber | 550µm reusable, Optional 800µm and 1000µm and 365µm | ||
Cooling system | Built-in water cooling system | ||
Dimensions | 89×45×90cm | ||
Weight | 130KG | 140KG | |
Power supply | AC 220V-240V/50Hz-60Hz, Single phase |
Holmium laser photoelectric characteristics:
1, "CE" certification, the quality of the most stable, the only domestic holmium laser certified by CE).
2, energy power closed loop feedback control system, automatic monitoring of output power to ensure that accurate and stable output power
On the basis of energy feedback system based on the re-use of accurate power loop control system, real-time monitoring of power changes, real-time adjustment of energy; ensuring a more stable power output.
3, the only photovoltaic holmium laser energy also has a closed-loop control system and built power stabilizer technology to ensure a stable output laser energy for a long time
4, with patented airtight laser cavity design technology
shock, moisture, dust, anti-electromagnetic interference, to create a good working environment for the activation of the elements holmium ensure holmium laser output quality, but also to ensure long-term stability of the laser output.
5, advanced fiber coupling technology
For a variety of specifications (200,300,400,600,800,1000μm) fiber conduction. East Cape photoelectric 200μm fiber through the CE certification, excellent flexibility, to maximize the soft lens curved to follow, with the energy of a closed-loop feedback control system, the output energy precise, stable and safe.
6, Quiet environmentally friendly forced cooling system
European imports host, ultra-quiet design, fast strong freon compressor refrigeration technology, remained stable. Make long continuous multiple laser surgery, without rest, domestic manufacturers in the longest continuous operation.
7, modular design, first-class laser individually removable, easy maintenance
Laser cavity, circuit control systems, power systems, cooling systems, display systems and other components using a modular approach designed to facilitate maintenance, while also reducing maintenance costs.
8, imported core components, quality assurance
Imported core components make the pump uniform, high conversion efficiency, high power holmium laser treatment, ultra stable, perfect performance and long life to provide a reliable guarantee.
9, color touch-screen LCD
Large screen, simple operation, at a glance, every 0.1 watts of power change real show
Standard Configuration,
Click here to download the User Manual,