- Description
The machine is open system.
Test channel: 2 testing channel
Heating well: 12 for sample, 5 for reagent
Each channel is independent ,one or two, same or different can be tested simutaneously
Auto pipette the measurement through configured pipette
Single point ,multipoint calibration, auto store and match with calibration curve
Calculative item: S , % , PTR , INR , FIB can get result through PT
Test Items: PT, APTT, TT, Fib, RepT, VT, AT-III, Protein-S, Protein-C, LA, Hep
Test Method: Dispersion light nephelometric analysis
Test Principle: The highest point on first order differentiation, Percentage analysis
Zero point correction: auto track the zero point, eliminate the interference of sample and reagent
Wavelength: 470nm
Light Source: Cold Lamp with high brightness and long lifetime
Detector: unique Dispersion light detector with high sensitivity and repeatability, immunized the effect
on result of jaundice,hemolysis,chyle and turbidity on plasma
Test Channel: each channel is independent, one or more,same or different items can be tested
Simultaneously
Incubator: Provide reagent and sample with stable incubator
Incubator Temperature: 37+/-0.2°C
Measure trigger: Auto trigger the measurement through configured pipette
Item modify: easy to add or edit items, easy to set the items parameters
Calibration: single-point calibration; multipoint calibration; auto store and match with calibration curve
Quality control: auto draw the quality figure
Reagent: Open reagent system
Reagent volume: ≤40μL
Sample volume: ≤40μL
Memory: Save more than 10000 samples results, and auto recovering the results when power is off during working .
Repeatability: CV≤5%
Calculative item: S,%,PTR,INR,Fib can be get through PT, This leads to lower the cost of reagent
Printer: Inner thermal printer,can be connected to external printer
Information edit: easy to input and edit the detail information of patients
Interface: RS-232 serial port,can be connected to external printer and computer
Working Environment: Temperature:10°C~30°C;Humidity:≤70%RH
Voltage: 85-264V,Auto adapt according to the input voltage
Power : ≤80W
Quality System: Recognized by CE, TUV and CMD.
Test Items
PT
APTT
TT
Fib
RepT
VT
AT-Ⅲ
Protein-S
Protein-C
LA
Hep
Standard Configuration
DESCRIPTION Quantity
Main unit, 1
Three-core Power line, 1
Earth line, 1
Pipette(20-200ul), 1
Pipette tip, 50
Cuvette cup, 40
Reagent cup, 4
Anticoagulant Tube, 5
Thermal Printer(57mm), 2
Operation manual, 1
Operation Guideline, 1
Service manual, 1
QC Passed, 1
Shipping Information:
G.W: 7kg
Packing Size: 0.44m,0.42m,0.35m
Unit: Piece
Special: No