- Description
Features:
1. Compatible with IV sets of any brand, universal type.
2. Automatically calibration for IV sets of any brand.
3. Three working modes: Drop counting control, Rate control and Time control mode.
4. 6 Hours continuous work when the battery is fully charged.
5. Have a unique color LCD and an internal battery with a high capability.
6. Switch between ml/h and drops/min freely.
7. Three levels of alarm volume: high, medium and low.
8. Three levels of occlusion pressure: high, medium and low.
9. KVO function: When finish the total volume of an infusion, the pump will alarm and enter KVO state.
Technical Specifications
1. Compatible with IV sets of any brand, universal type.
2. Automatically calibration for IV sets of any brand.
3. Three working modes: Drop counting control, Rate control and Time control mode.
4. 6 Hours continuous work when the battery is fully charged.
5. Have a unique color LCD and an internal battery with a high capability.
6. Switch between ml/h and drops/min freely.
7. Three levels of alarm volume: high, medium and low.
8. Three levels of occlusion pressure: high, medium and low.
9. KVO function: When finish the total volume of an infusion, the pump will alarm and enter KVO state.
Technical Specifications
PARAMETER | SPECIFICATION |
Drop Detector | Outside caliper rotary detector (patent) Infrared sensor |
Control Way | Drop counting and adjusting the delivery rate automatically |
Fit IV tubes | 20d/ml,60d/ml and other, as well as brown tubes |
Pump Type | Peristaltic finger pump |
Accuracy | ±2%, when delivery rate ≤25drop/min (drop counting & time control mode) ±3%, when delivery rate >25drop/min (drop counting & time control mode) ±5% (Volume control mode after the correct calibration) |
Delivery rate range | 1-1999min (1min step) |
Volume limit range: | 0-9999ml (1 ml step) |
Total Volume Range | 0-9999.9ml (1 ml step) |
Purge Rate | 600.0ml/h |
KVO Rate | KVO is 1ml/h when the delivery rate≤10ml/h, Otherwise KVO is 3ml/h. |
Occlusion pressure | Three level setting LOW, MEDIUM or HIGH |
Alarms | Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures. Three levels of alarm volume LOW, MEDIUM or HIGH |
Bolus function | Bolus rate:10-1200ml/h,Bolus volume: maximum of 100ml |
Power source | AC power supply: AC 100 to 240V( +/-10%),50/60Hz; Built-in Lithium Battery: Rechargeable,11.1V,2000mAh. 6 hours of continuous operation |
Accessories: | AC power line, Operational manual |
Protection Class | Class I, Type CF,IPX4 |
Dimension /Net weight | 130mm*200mm*230mm , 2.5kg |