Double Channel Syringe Pump Double Channel Syringe PumpDouble Channel Syringe PumpDouble Channel Syringe Pump
Cheap, Various, Quality, Fast Shipping
Your position: Home > Product By Name > Infusion Injection Pump

Double Channel Syringe Pump

1. Universal syringe set: 5ml,10ml,20ml,30ml,50ml,60ml. 2. Automatically detection of syringe types and remained solution. 3. Broad range in delivery rate settings. 3. 6 Hours continuous work after fully charged.
Item Code: CCS-1800D
Sold: 50
    Please select the information you wantX
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
+
-
Units
  • Description
Features:
1. Universal syringe set: 5ml,10ml,20ml,30ml,50ml,60ml.
2. Automatically detection of syringe types and remained solution.
3. Broad range in delivery rate settings.
3. 6 Hours continuous work after fully charged.
4. Three levels of alarm volume: high, medium and low.
5. Three levels of occlusion pressure: high, medium and low.
6. KVO function:After infusion is complete, the pump automatically switches to the smallest flow to prevent creating the thrombus. 
 
OEM  Service  Available
 
CE/ISO13485 Marked   
Technical Specifications

 
PARAMETER SPECIFICATION
Applicable syringes 10ml,20ml,30ml,50ml,60ml of any standard
Accuracy +/- 2% with correct calibration
Rate mode 50ml(60ml):0.1ml/h-1800.0ml/h (0.1ml/h step)
20ml(30ml):0.1ml/h-800.0ml/h (0.1ml/h step)
10ml:0.1ml/h-400.0ml/h (0.1ml/h step)
Time Mode SOL. VOL:0.1-999.9ml (0.1ml step)
TIME:1-1999min (1min step)
Body Weight Mode: Volume:0.1-999.9ml(0.1ml step)
DRUG MASS:0.1-999.9mg 0.1mg step)
DOSE:0.01-99.99ug/kg/min(0.01ug/kg/min step)
WEIGHT:0.1-300kg(0.1kg the least step)
Total Volume Range 0.1-1999.9ml (0.1 ml step)
Purge Rate 50ml(60ml):1800.0ml/h,
20ml(30ml):800.0ml/h,
10ml:400.0ml/h
KVO Rate 1ml/h
Occlusion pressure Three level setting LOW, MEDIUM or HIGH
Alarms Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.
Three levels of alarm volume LOW, MEDIUM or HIGH
Bolus Rate 10ml:10-300ml/h,20ml(30ml):10-600ml/h,
50ml(60ml):10-1200ml/h
Bolus Volume Maximum of 25ml
Interface RS-232, Reserved port
Power source AC power supply: AC 100 to 240V( +/-10%),50/60Hz;
Built-in Lithium Battery:  Rechargeable, 11.1V, 2000mAh.
6 hours of continuous operation.
Accessories: AC power line, Operational manual
Protection Class Class I, Type CF,IPX4
Dimension /   Net weight             300mm*240mm*250mm , 3.6kg

Shipping Information:

G.W: 4.8kg

Packing Size: 0.34m,0.32m,0.26m

Unit: Piece

Special: No