- Description
- Catalog
Specifications
Type:
Trolley
automatic leak compensation function and so on. IFlow closed- loop pressure control system delivers high- precision,
safe fresh gas to protect fragile new life.Humanized operating system closely integrated with clinical practice
streamline workflow for medical staff. Integrated solution with SNIPPV/NIPPV, NCPAP and HFNC ventilation modes.
Oxygen concentration automatic
calibration Further reduce human error, offering high precision oxygen concentration monitoring.
Power-on self-test function
Reduce the wait time of medical staff, using it with peace of mind.
LCD touch screen
Clear, bright 8- inch LCD screen;
Touch operation; Clearly visible from
any angle and distance; Monitoring
data display is conspicuous; Visualized setting reduces human error, allowing
doctors to focus on newborns.
Features
Specially designed handle, round and
non- angular, adopting skin- friendly material for comfortable grip.
360° alarm light design, eye-catching and good- looking, allowing the medical staff to notice alarm situation in time.
The stand is made of all-aluminum alloy, portable and reliable. The pedestal stand is specially designed for Comen air
compressors, with less resonance and noise.
Exceptional apnea wakeup function
The incidence of apnea in premature infants can be as high as 50% to
60%, and the smaller gestational age, the higher incidence.
NV8 provides reliable apnea monitoring through the abodominal sensor
with apnea wake- up function, effectively reducing the incidence of apnea.
Abdominal sensor: The breathing mode of newborns is abdominal
breathing. When breathing, their abdominal undulation is obvious. The
sensor is attached to the newborn's abdomen, and the respiratory motion squeezes the sensor to convert the respiratorymotion signal into an
electrical signal for system identification and recognition.
NIPPV (Nasal intermittent positive pressure ventilation)
Increasing the pressure of the upper respiratory tract by intermittently
increasing pharyngeal pressure, and encouraging respiratory movements by intermittent laryngeal expansion, NIPPV can produce higher average
airway pressure than CPAP and can increase alveolar filling. This would
effectively improve oxygenation and ventilation, reduce patient’s work
of breathing (WOB), and increase functional residual capacity (FRC)
Provides up to 15 seconds of inhalation time, ensuring smooth and spontaneous breathing under bilevel pressure
SNIPPV (synchronized nasal intermittent positive
pressure ventilation) + backup ventilation)
Synchronization with breathing: when patients inhale, their abdomen goes up and triggers the sensor to send out inspiratory pressure
synchronically, reducing man- machine confrontation and WOB,
smoothing the breath
Abdomen attached respiration sensor: accurately identify respiratory waveform, realize synchronous trigger and precisely monitor
respiratory rate (RR)
Backup ventilation: when patient stops breathing for longer than
the preset apnea interval, NV8 will automatically switch to backup
ventilation and ventilate patient as per preset RR to prevent sleep apnea
HFNC (High flow nasal cannula) + pressure monitoring function,
Compared with traditional oxygen therapy instrument, NV8 makes real- time pressure monitoring and waveform display possible,
ensuring ventilation safety under HFNC mode and preventing
unintended consequences due to overpressure,
Comes standard with Fisher&Paykel humidifier, providing warm and humidified fresh gas for newborns
Direct pressure setting,
Traditional CPAP devices have low degree of automation. Indirect pressure control is realized
by manually adjusting flow, which requires repetitive manual observation and adjustment. And remote
monitoring of pressure fails to truly reflect the airway pressure at the patient end. pressure control mode: automatic pressure
control is realized by directly setting the pressure value.
Direct setting of oxygen concentration,
Traditional CPAP devices adopt mechanical air- oxygen blender, or oxygen and air flow meters combination, which is
cumbersome to operate and the accuracy is easily affected due to mechanical wear. The NV8 uses electronic air- oxygen blender: directly sets the oxygen concentration value, automatically matches the ratio of oxygen and air flow, and cooperates with high- precision flow sensor and flow
proportional valve to achieve real- time feedback and oxygen concentration control (precision within ±3%).
Incorporates with Medin company's Medijet pressure generator; patented technology employing Coanda effect; produce positive airway pressure
Near- nose gas exhalation, which is
more conducive to reducing CO2
retention and could reduce up to 75% WOB compared to traditional CPAP devices.
Multi- size soft silicone nasal plugs, nasal masks and cotton bonnets for premature infants weighing as low
as 500 grams, easy to wear.
The machine can be with compressor optional, if you need that, welcome to inquiry us.