- Description
Characters:
Proven method: Fixed time nephelometry
4 independent working channel
Small sample volume
Calibrated against the International Reference Material CRM470
5.6-inch touch screen operation with intuitive software
Support barcode scanner
Built-in thermal printer, support auto & manual print
Certified by NGSP (National Glycohemoglobin Standardization Program)
Test Principle:Nephelometry.
Parameters: hsCRP、HbA1c、mALB、D-Dimer、ASO、RF、C3、C4 etc.can be extended to more than 30 parameters.
Light source: Diode laser,wavelength 650nm.
Testing channel:4 independant channel,can test same sample or different samples simultaneously. 1 channel is available.
Sample type: Whole blood、Serum、plasma、urine etc.
Sample volume:2ul~100uL.
Reagent volume:20~100uL.
Throughput:150 samples/per hour.
Accuracy:Maximum precision and highest sensitivity. Blank measurement is automatically processed in the same cuvette. CV<5%
Reference:Calibrated against the International Reference Material CRM470
Calibration:Magnetic card system. No need to do calibration curve.
Temperature control:Auto temperature control and mixing.
Test step: Reagent prepared in the cuvette from factory,easy to operate. Results can be reported within 15 seconds to 2 minutes
Display: 5.6 inch high resolution color touch screen.
Storage : Can be saved 10000 sample data,and can be extended by SD card
Interface:COM RS-232 .
Device extension:。Compatable with bar code reader, LIS and HIS.
Printer: Built-in Thermal printer.auto and manual printing is optional.
Working temperature::15℃~35℃;Humidity:≤85%RH。
Voltage:~100--240V,50/60Hz。
Power:≤ 60VA。
CRP Assay in whole blood
Assay range: 0.8-300 mg/L
Only 2-20 ul venous or capillary blood required
Results available with 2 minutes
HbA1C assay
One step latex-enhanced direct method, no need for determination of total hemoglobin
Results according to NGSP or IFCC
Time saving
Assay range: 3-15%
Standard Configuration:
Main Unit
Test principle : Nephelometry
Parameters: hsCRP,HbA1c,mALB, D-Dimer,ASO,RF,C3,etc.
Testing channel : one channel,one samples can be tested at a time.
Sample type: Whole blood, Serum, Plasma, Urine etc.
Sample volume: 2 μl ~ 100 μl. Reagent volume : 20 μl ~ 100 μl
Reagent: close system, and reagent are pre-packed.
DESCRIPTION, Quantity
Main Unit , 1
Power cord (1.8m), 1
Pipette Tips Packing Box, 1
Pipettor(0.5-10ul), 1
Pipettor(20-200ul), 1
Pipette Tips, 1
Thermal Print Paper(57mm*35mm), 100
Operation Manual, 1
Service Manual, 1
Brief Operation Guideline, 1
Quality Certificate, 1
Ground cable, 1
Packing List, 1
Optional
Reagent and cuvette
Printer paper 57mm*35mm (1 roll)
Reaction cuvette (100 pcs)
CRP Kit (50 tests)
CRP Kit (100 tests)
HbA1c Kit (25 tests)
HbA1c Kit (50 tests)
mALB Kit (50 tests)
mALB Kit (100 tests)
RF Kit (50 tests)
RF Kit (100 tests)
ASO Kit (50 tests)
ASO Kit (100 tests)
CYS-C Kit (50 tests)
CYS-C Kit (100 tests)
CCP Kit (50 tests)
CCP Kit (100 tests)
D-Dimer Kit (25 tests)
D-Dimer Kit (50 tests)
QC
QC for mALB (0.2ml)
QC for hs-CRP(0.2ml)
QC for HbA1c (High level 0.5 ml / Medium level 0.5 ml)
QC for D-DIMER( 0.5ml)
QC for ASO ( Randox 1ml)
QC for RF ( Randox 1ml)
Shipping Information:
G.W: 9kg
Packing Size: 0.6m,0.5m,0.3m
Unit: Piece
Special: No