Syringe Pump with drug library Syringe Pump with drug librarySyringe Pump with drug librarySyringe Pump with drug library
Cheap, Various, Quality, Fast Shipping
Your position: Home > Product By Name > Infusion Injection Pump

Syringe Pump with drug library

1.Compatible with disposable syringes from 5ml,10ml,20ml,30ml,50ml,60ml. 2.Stackable to be the maximum 8 channels. 3.High accuracy +/-2% after correct calibrated. 4.Three work modes: Rate mode, Time mode and Weight mode. 5.Bolus / Purge, KVO function.
Item Code: CCS-1800G
Sold: 50
    Please select the information you wantX
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
+
-
Units
  • Description
Features:
  1. Compatible with disposable syringes from 5ml,10ml,20ml,30ml,50ml,60ml.
  2. Stackable to be the maximum 8 channels.
  1. High accuracy +/-2% after correct calibrated.
  2. Three work modes: Rate mode, Time mode and Weight mode.
  3. Bolus / Purge, KVO function.
  4. With drug libraries:10 categories of common drugs,174 kinds in total.
  5. History recorded, real time displayed
  6. 6 hours continuous work after fully charged.
 
OEM Service Available
CE/ISO13485 Marked
 

 
Technical Specifications
 
PARAMETER SPECIFICATION
Applicable syringes 5ml,10ml,20ml,30ml,50ml,60ml of any standard
Accuracy +/- 2% with correct calibration
Rate mode 50ml(60ml):0.1ml/h-1800.0ml/h (0.1ml/h step)
20ml(30ml):0.1ml/h-800.0ml/h (0.1ml/h step)
10ml:0.1ml/h-400.0ml/h (0.1ml/h step)
Time Mode SOL. VOL:0.1-999.9ml (0.1ml step)
TIME:1-1999min (1min step)
Body Weight Mode: Volume:0.1-999.9ml(0.1ml step)
DRUG MASS:0.1-999.9mg 0.1mg step)
DOSE:0.01-99.99ug/kg/min(0.01ug/kg/min step)
WEIGHT:0.1-300kg(0.1kg the least step)
Total Volume Range 0.1-1999.9ml (0.1 ml step)
Purge Rate 50ml(60ml):1800.0ml/h,
20ml(30ml):800.0ml/h,
10ml:400.0ml/h, 5ml: 200ml/h
KVO Rate 1ml/h
Occlusion pressure Three level setting LOW, MEDIUM or HIGH
Alarms Near empty, Syringe empty, Volume complete (when limit volume is set), Occlusion, Syringe loose, Operation error, Low battery, device failures.
Three levels of alarm volume LOW, MEDIUM or HIGH
Bolus Rate 10ml:10-300ml/h,20ml(30ml):10-600ml/h,
50ml(60ml):10-1200ml/h
Bolus Volume Maximum of 25ml
Interface RS-232  (Reserved port)
Power source AC power supply: AC 100 to 240V( +/-10%),50/60Hz;
Built-in Lithium Battery:  Rechargeable, 11.1V, 2000mAh.
8 hours of continuous operation.
Accessories: AC power line, Operational manual
Protection Class Class I, Type CF,IPX4
Dimension / Net weight 230mm*150mm*125mm , 2.2kg

Shipping Information:

G.W: 3kg

Packing Size: 0.3m,0.25m,0.16m

Unit: Piece

Special: No

Name: